〔Standard〕
(DB□□□-2)
〔10%ED〕
(DB□□□-2C)
Braking resistor types | Inverter type | Braking resistor model | Resistance [Ω] | Max. braking torque | Continuous braking (100% torque conversion value) |
Repeated braking (frequency 100 [s] or less) |
||||
---|---|---|---|---|---|---|---|---|---|---|
[%] | 50Hz | 60Hz | Discharge withstand current rating [kWs] |
Braking time [s] |
Allowable average loss [kW] |
Utilization rate [%ED] |
||||
[N・m] | [N・m] | |||||||||
Standard | V7-04-4 | DB0.75-2 | 100 | 150 | 4.02 | 3.32 | 9 | 45 | 0.044 | 22 |
V7-07-4 | DB0.75-2 | 100 | 150 | 7.57 | 6.25 | 17 | 45 | 0.068 | 18 | |
V7-15-4 | DB2.2-2 | 40 | 150 | 15.0 | 12.4 | 34 | 45 | 0.075 | 10 | |
V7-22-4 | DB2.2-2 | 40 | 150 | 22.0 | 18.2 | 33 | 30 | 0.077 | 7 | |
V7-37-4 | DB3.7-2 | 33 | 150 | 37.1 | 30.5 | 37 | 20 | 0.093 | 5 | |
10%ED | V7-04-4 | DB0.75-2C | 100 | 150 | 4.02 | 3.32 | 50 | 250 | 0.075 | 37 |
V7-07-4 | DB0.75-2C | 100 | 150 | 7.57 | 6.25 | 50 | 133 | 0.075 | 20 | |
V7-15-4 | DB2.2-2C | 40 | 150 | 15.0 | 12.4 | 55 | 73 | 0.110 | 14 | |
V7-22-4 | DB2.2-2C | 40 | 150 | 22.0 | 18.2 | 55 | 50 | 0.110 | 10 | |
V7-37-4 | DB3.7-2C | 33 | 150 | 37.1 | 30.5 | 140 | 75 | 0.185 | 10 |
Types | Model | Figure | W[mm] | H[mm] | H1[mm] | D[mm] | Mass[kg] |
---|---|---|---|---|---|---|---|
Standard | DB0.75-2 | A | 68 | 310 | 295 | 67 | 1.3 |
DB2.2-2 | A | 80 | 345 | 332 | 94 | 2.0 | |
DB3.7-2 | A | 80 | 345 | 332 | 94 | 2.0 | |
10%ED | DB0.75-2C | B | 43 | 221 | 215 | 30.5 | 0.4 |
DB2.2-2C | C | 67 | 188 | 172 | 55 | 0.8 | |
DB3.7-2C | C | 67 | 328 | 312 | 55 | 1.4 |
[Small type] (TK80W120 Ω)
Model | Resistance | Applied inverter model | Average braking torque[%] | Allowable braking characteristic | Braking unit | ||
---|---|---|---|---|---|---|---|
Capacity[kW] | Resistance[Ω] | Allowable braking frequency[%] | Allowable continuous braking time[s] | ||||
TK80W120Ω | 0.08 | 120 | V7-04-4 | 150 | 15 | 15 | No need |
V7-07-4 | 150 | 5 | 15 | No need | |||
V7-15-4 | 150 | 5 | 10 | No need | |||
V7-22-4 | 65 | 5 | 10 | No need | |||
V7-37-4 | 45 | 5 | 10 | No need |
Applied inverter model | Reactor model |
W[mm] | W1[mm] | D[mm] | D1[mm] | D2[mm] | G[Nominal dia.] | H[mm] | J[Nominal dia.] | Mass[kg] |
---|---|---|---|---|---|---|---|---|---|---|
V7-01-4 | DCR2-0.2 | 66 | 56 | 90 | 72 | 5 | M4 | 94 | M4 | 0.8 |
V7-02-4 | DCR2-0.2 | 66 | 56 | 90 | 72 | 5 | M4 | 94 | M4 | 0.8 |
V7-04-4 | DCR2-0.4 | 66 | 56 | 90 | 72 | 15 | M4 | 94 | M4 | 1.0 |
V7-07-4 | DCR2-0.75 | 66 | 56 | 90 | 72 | 20 | M4 | 94 | M4 | 1.4 |
V7-15-4 | DCR2-1.5 | 66 | 56 | 90 | 72 | 20 | M4 | 94 | M4 | 1.6 |
V7-22-4 | DCR2-2.2 | 86 | 71 | 100 | 80 | 10 | M5 | 110 | M4 | 1.8 |
V7-37-4 | DCR2-3.7 | 86 | 71 | 100 | 80 | 20 | M5 | 110 | M4 | 2.6 |
By using this voltage doubler unit, 0.75 kW or lower models (3-phase 200 V input) can be used in with a single-phase 100 V power supply.
The driving motor is three-phase 200 V.
*Rated input AC voltage: Single-phase 100 to 115 V, 50/60 Hz
*Rated output voltage: 255 to 280 VDC
【Rated capacity】
Applied inverter model | Voltage doubler unit model | Rated capacity [kVA] |
---|---|---|
07-01-4 | CAPA6-0.2 | 0.5 |
07-02-4 | CAPA6-0.2 | 0.5 |
07-04-4 | CAPA6-0.4 | 1.1 |
07-07-4 | CAPA6-0.75 | 1.8 |
The remote touchpanel allows you to remotely operate and display data for the V series (with copy function).
※Requires a separate extension cable for remote operation.
Cable for connecting the remote touch panel via RS-485 communication.
Straight cable is available in 3 lengths: 1, 3, and 5m.
Model | Length L [m] |
---|---|
CB-1S | 1 |
CB-3S | 3 |
CB-5S | 5 |
The output frequency can be measured by connecting the frequenc y meter to control circuit terminals FMA and 11 on the inverter.