Features of V7 INVERTER
Featuring the one of the fastest available CPUs, the new V7 inverters offer twice the calculating power of the current V6 models, giving them outstanding performance in this class of inverters. Miki Pulley’s original dynamic torque vector control system is also used to ensure stable operation at low speeds. These models also retain the ease of use typical of the rest of the series, and are fully compatible with respect to external dimensions, installation dimensions, number and location of terminals, etc. In response to popular demand, they also include an RS-485 communications port. These are compact yet powerful, fully featured inverters.
Options of V7 INVERTER
Braking resistor
〔Standard〕
(DB□□□-2)
〔10%ED〕
(DB□□□-2C)
Braking resistor types |
Inverter type |
Braking resistor model |
Resistance
[Ω] |
Max. braking torque |
Continuous braking
(100% torque conversion value) |
Repeated braking (frequency 100 [s] or less) |
[%] |
50Hz |
60Hz |
Discharge withstand current rating
[kWs] |
Braking time
[s] |
Allowable average loss [kW] |
Utilization rate
[%ED] |
[N・m] |
[N・m] |
Standard |
V7-04-4 |
DB0.75-2 |
100 |
150 |
4.02 |
3.32 |
9 |
45 |
0.044 |
22 |
V7-07-4 |
DB0.75-2 |
100 |
150 |
7.57 |
6.25 |
17 |
45 |
0.068 |
18 |
V7-15-4 |
DB2.2-2 |
40 |
150 |
15.0 |
12.4 |
34 |
45 |
0.075 |
10 |
V7-22-4 |
DB2.2-2 |
40 |
150 |
22.0 |
18.2 |
33 |
30 |
0.077 |
7 |
V7-37-4 |
DB3.7-2 |
33 |
150 |
37.1 |
30.5 |
37 |
20 |
0.093 |
5 |
10%ED |
V7-04-4 |
DB0.75-2C |
100 |
150 |
4.02 |
3.32 |
50 |
250 |
0.075 |
37 |
V7-07-4 |
DB0.75-2C |
100 |
150 |
7.57 |
6.25 |
50 |
133 |
0.075 |
20 |
V7-15-4 |
DB2.2-2C |
40 |
150 |
15.0 |
12.4 |
55 |
73 |
0.110 |
14 |
V7-22-4 |
DB2.2-2C |
40 |
150 |
22.0 |
18.2 |
55 |
50 |
0.110 |
10 |
V7-37-4 |
DB3.7-2C |
33 |
150 |
37.1 |
30.5 |
140 |
75 |
0.185 |
10 |
Types |
Model |
Figure |
W[mm] |
H[mm] |
H1[mm] |
D[mm] |
Mass[kg] |
Standard |
DB0.75-2 |
A |
68 |
310 |
295 |
67 |
1.3 |
DB2.2-2 |
A |
80 |
345 |
332 |
94 |
2.0 |
DB3.7-2 |
A |
80 |
345 |
332 |
94 |
2.0 |
10%ED |
DB0.75-2C |
B |
43 |
221 |
215 |
30.5 |
0.4 |
DB2.2-2C |
C |
67 |
188 |
172 |
55 |
0.8 |
DB3.7-2C |
C |
67 |
328 |
312 |
55 |
1.4 |
Braking resistor [Small type]
[Small type]
(TK80W120 Ω)
Model |
Resistance |
Applied inverter model |
Average braking torque[%] |
Allowable braking characteristic |
Braking unit |
Capacity[kW] |
Resistance[Ω] |
Allowable braking frequency[%] |
Allowable continuous braking time[s] |
TK80W120Ω |
0.08 |
120 |
V7-04-4 |
150 |
15 |
15 |
No need |
V7-07-4 |
150 |
5 |
15 |
No need |
V7-15-4 |
150 |
5 |
10 |
No need |
V7-22-4 |
65 |
5 |
10 |
No need |
V7-37-4 |
45 |
5 |
10 |
No need |
DC reactor (DCR)
Applied inverter model |
Reactor model |
W[mm] |
W1[mm] |
D[mm] |
D1[mm] |
D2[mm] |
G[Nominal dia.] |
H[mm] |
J[Nominal dia.] |
Mass[kg] |
V7-01-4 |
DCR2-0.2 |
66 |
56 |
90 |
72 |
5 |
M4 |
94 |
M4 |
0.8 |
V7-02-4 |
DCR2-0.2 |
66 |
56 |
90 |
72 |
5 |
M4 |
94 |
M4 |
0.8 |
V7-04-4 |
DCR2-0.4 |
66 |
56 |
90 |
72 |
15 |
M4 |
94 |
M4 |
1.0 |
V7-07-4 |
DCR2-0.75 |
66 |
56 |
90 |
72 |
20 |
M4 |
94 |
M4 |
1.4 |
V7-15-4 |
DCR2-1.5 |
66 |
56 |
90 |
72 |
20 |
M4 |
94 |
M4 |
1.6 |
V7-22-4 |
DCR2-2.2 |
86 |
71 |
100 |
80 |
10 |
M5 |
110 |
M4 |
1.8 |
V7-37-4 |
DCR2-3.7 |
86 |
71 |
100 |
80 |
20 |
M5 |
110 |
M4 |
2.6 |
Voltage Doubler Unit
By using this voltage doubler unit, 0.75 kW or lower models (3-phase 200 V input) can be used in with a single-phase 100 V power supply.
The driving motor is three-phase 200 V.
*Rated input AC voltage: Single-phase 100 to 115 V, 50/60 Hz
*Rated output voltage: 255 to 280 VDC
【Rated capacity】
Applied inverter model |
Voltage doubler unit model |
Rated capacity [kVA] |
07-01-4 |
CAPA6-0.2 |
0.5 |
07-02-4 |
CAPA6-0.2 |
0.5 |
07-04-4 |
CAPA6-0.4 |
1.1 |
07-07-4 |
CAPA6-0.75 |
1.8 |
Remote Touch Panel (TP-E1)
The remote touchpanel allows you to remotely operate and display data for the V series (with copy function).
※Requires a separate extension cable for remote operation.
Extension Cable for Remote Operation
Cable for connecting the remote touch panel via RS-485 communication.
Straight cable is available in 3 lengths: 1, 3, and 5m.
Model |
Length L [m] |
CB-1S |
1 |
CB-3S |
3 |
CB-5S |
5 |
Frequency Setter <for VR Set 24 (B5K Ohm)>
Frequency Meter (TRM-45-V6)
The output frequency can be measured by connecting the frequenc y meter to control circuit terminals FMA and 11 on the inverter.