Product Information

BE Models (For ordinary control)

ダウンロード

BE Models (For ordinary control) Specifications

BE Models

[Specifications]

ModelBE-05BE-10BE-20BE-40BER-05BER-10BER-20BEZ-10BEZ-20
Dimensions/TypeRefer to the List of DimensionsType 1Type 2Type 3Type 4Type 2Type 3Type 4Type 2Type 3
Input voltageAC 100 V± 10% 50 Hz/60 Hz
AC 110 V
AC 200 V
AC 220 V
Output voltageTransformer stepdown/Single-phase full-wave rectification/Non-smoothingDC 24 VDC 24 V output, internal relayDC 21.5 V
Rated/capacityContinuous rating25 W50 W100 W200 W25 W50 W100 W56.6 W114 W
Size setting◎: Accepts two or more connections ●: Applicable △: Applicable depending on clutch or brake model011212
02  1313
031515
04  2121
052323
06  2525
083131
10  3232
12 
14      
16 
18     
20   
25     
31   
40     
Applicable clutches/brakesMiki Pulley clutches and brakes, Rated voltage: DC 24 VElectromagnetic clutches and brakes,
spring-actuated brakes,
other standard control applications
Switching control applications for clutch & brake unitsTooth clutch applications
Protection functionFast-acting fuse, input side1 A1 A3 A5 A1 A1 A3 A3 A3 A5 A5 A
Usage environmentWith no condensation0℃ to +50℃/10% to 90% RH
MassPer product1.4 kg2.4 kg4.0 kg6.4 kg1.6 kg3.0 kg4.9 kg3.4 kg3.4 kg4.4 kg4.4 kg

[Dimensions]

Unit[mm]
DimensionsType No.
Type 1Type 2Type 3Type 4
A95105120130
B8090105105
C130160180230
D115145165215
E75100120135
CAD File No.BE3BE4BE5BE6

[Structure]

[Characteristics]

Output type

Using a transformer to step-down the voltage and perform full-wave rectification on single-phase power from a commercial power supply produces a DC voltage output of 24 V DC. The output voltage may be affected by pulses as the signal is not smoothed, but these pulses should not have any effect on normal, daily operation of electromagnetic clutches and brakes. For applications requiring highly accurate clutch and brake responsiveness with no fluctuations in voltage whatsoever, use a power supply with a smoothed supply voltage or a Miki Pulley BEH model power supply

Power supply voltage fluctuations and output voltage

This power supply device experiences fluctuations in output voltage at the same rate as it experiences fluctuations in input voltage. Keep power supply voltage fluctuations to within a range of ±10% to maintain normal operation.

[Wiring methods and timing charts]

Basic wiring method for BE models

Wiring method for BER models (Single-step control)

Wiring method for BER models (Single-signal control)

Basic wiring method for BEZ models