BEW Models
[Specifications]
Model | BEW-2G | BEW-4G | BEW-1R | BEW-2R | BEW-4R | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input voltage | AC100V | ± 10% 50 Hz/60 Hz | ● | ● | ● | ● | |||||||
AC200V | ● | ● | ● | ● | |||||||||
AC400V | ● | ● | ● | ||||||||||
Input voltage range | AC 280 V max. | AC 480 V max. | AC90 ~ 140V | AC180 ~ 280V | AC360 ~ 480V | ||||||||
Rectification method | Half-wave rectification | For both half- and full-wave rectification | |||||||||||
Half-wave | Full-wave | Half-wave | Full-wave | Half-wave | Full-wave | ||||||||
Output voltage | DC45V | DC90V | DC45V | DC90V | DC180V | DC45V | DC90V | DC90V | DC180V | DC180V | DC360V | ||
Output current | When the ambient temperature is 20℃ values in () are for an ambient temperature of 60℃ | DC1.0A (DC0.7A) | DC1.0A(DC0.7A) | DC2.0A (DC1.5A) | DC1.0A(DC0.7A) | DC0.7A (DC0.5A) | |||||||
Output Wattage | When the ambient temperature is 20℃ values in () are for an ambient temperature of 60℃ | 45 W (25 W) | 90 W (50 W) | 45 W (25 W) | 90 W (50 W) | 180 W (100 W) | 90 W (50 W) | 180 W (100 W) | 90 W (50 W) | 180 W (100 W) | 126 W (90 W) | 252 W (180 W) | |
Size settings | Voltage specifications Numbers in parentheses are input voltages | DC45V (AC100V) | DC90V (AC200V) | DC45V (AC100V) | DC90V (AC200V) | DC180V (AC400V) | DC45V (AC100V) | DC90V (AC100V) | DC90V (AC200V) | DC180V (AC200V) | DC180V (AC400V) | DC360V (AC400V) | |
●: Applicable △: Applicable depending on clutch/brake model | 01 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
02 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||
03 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||
04 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||
05 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||
06 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||
08 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||
10 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||
12 | ● | ● | ● | ● | ● | ● | ● | ||||||
14 | ● | ● | ● | ● | ● | ● | ● | ||||||
16 | ● | ● | ● | ● | ● | ● | ● | ||||||
18 | △ | △ | ● | ● | △ | ● | ● | ||||||
20 | △ | △ | ● | ● | △ | ● | ● | ||||||
25 | △ | △ | ● | ● | △ | ● | ● | ||||||
Applicable clutches/brakes | Miki Pulley Clutches & Brakes, Rated voltage: DC 45/90/180 V | Spring-actuated brake | All | ||||||||||
Insulating resistance | Between terminal and body | DC 500 V, 100 M Ω with Megger | |||||||||||
Dielectric strength voltage | Between terminal and body | 1500 V AC, 50 Hz, 1 min. | 2000 V AC, 50 Hz, 1 min. | 1500 V AC, 50 Hz, 1 min. | 2000 V AC, 50 Hz, 1 min. | ||||||||
Usage environment | With no condensation | -20℃ to +60℃ | |||||||||||
Mass | Per product | 0.04 kg |
[Dimensions]
[Structure]
[Terminals and Functions]
Model | Terminal symbol | Terminal name | Function description |
---|---|---|---|
BEW(G) | 1-2 | Power supply input terminal | Connector for a commercial power supply |
2-3 | Control terminal | Output is controlled by opening and closing between terminals with a relay or other contact | |
3-4 | Output terminal | Connector for an electromagnetic clutch or brake | |
BEW(R) | 1-2 | Power supply input terminal | Connector for a commercial power supply |
2-4 | Output terminal (half-wave) | Connector for an electromagnetic clutch or brake (when half-wave rectified) | |
3-4 | Output terminal (full-wave) | Connector for an electromagnetic clutch or brake (when full-wave rectified)) |
[Characteristics]
Output type
[Wiring Methods and Timing Charts]
BEW(G) Secondary Control (Basic Wiring)
BEW(G) Primary Control (Wire Saving)
BEW(G) Secondary Control (Wire Saving)
BEW(R) Primary Control