Product Information

SFC Models Specifications

SFC-□SA2 Types

[Specifications]

ModelTypeRated torque
[N・m]
MisalignmentMax. rotation speed
[min-1]
Torsional stiffness
[N・m/rad]
Axial stiffness
[N/mm]
Moment of inertia
[kg・m2]
Mass[kg]
Parallel[mm]Angular[゜]Axial[mm]
SFC-002SA2C0.250.010.5±0.0410000190340.06×10-60.003
SFC-005SA2C0.60.020.5±0.05100005001400.26×10-60.007
SFC-010SA2C10.021±0.11000014001400.58×10-60.011
SFC-020SA2C20.021±0.15100003700642.39×10-60.025
SFC-025SA2C40.021±0.19100005600603.67×10-60.029
SFC-030SA2A50.021±0.2100008000644.07×10-60.034
B6.09×10-60.041
C8.20×10-60.049
SFC-035SA2C100.021±0.25100001800011218.44×10-60.082
SFC-040SA2A120.021±0.310000200008016.71×10-60.077
B22.55×10-60.085
C29.25×10-60.100
SFC-050SA2A250.021±0.410000320004855.71×10-60.159
B76.26×10-60.177
C99.03×10-60.206
SFC-055SA2C400.021±0.42100005000043188.0×10-60.314
SFC-060SA2A600.021±0.45100007000076.4145.9×10-60.283
B205.0×10-60.326
C268.6×10-60.385
SFC-080SA2C1000.021±0.5510000140000128710.6×10-60.708
SFC-090SA2C1800.021±0.65100001000001081236×10-60.946
SFC-100SA2C2500.021±0.74100001200001111891×10-61.202

* Types A / B / C are automatically specified by Miki Pulley according to the combination of bore diameters you select, and cannot be specified by the customer.

* Check the Standard Bore Diameter list as rated torque may be restricted by the holding power of the shaft connection component.

* Max. rotation speed does not take into account dynamic balance.

* Torsional stiffness values given are measured values for the element alone.

* The moment of inertia and mass are measured for the maximum bore diameter.

[Dimensions]

Unit [mm]
ModelTyped1[mm]d2[mm]D[mm]DB[mm]N[mm]L[mm]LF[mm]S[mm]A1[mm]A2[mm]C[mm]K[mm]M
Qty - Nominal dia
Tightening torque[N・m]
Min. Max.Min. Max.
SFC-002SA235351212.412.355.90.553.71.95.61-M1.60.23 to 0.28
SFC-005SA2C36361616.77.8514.82.56.51-M20.4 to 0.5
SFC-010SA2C38381919.359.151.055.8(6)3.158.51-M2.5(M2)1.0 to 1.1(0.4 to 0.5)
SFC-020SA2C4104112623.1510.751.659.53.310.61-M2.51.0 to 1.1
SFC-025SA2C5145142923.410.751.9113.314.51-M2.51.0 to 1.1
SFC-030SA2A5105103421.627.312.42.583.7514.51-M31.5 to 1.9
B510Over 1016812.5
COver 1014Over 101612.5
SFC-035SA2C616619393415.53144.5171-M43.4 to 4.1
SFC-040SA2A8158154429.63415.53114.519.51-M43.4 to 4.1
B815Over 15241117
COver 1519Over 152417
SFC-050SA2A819819563843.420.52.414.56261-M57.0 to 8.5
B819Over 193014.522
COver 1925Over 193022
SFC-055SA2C103010306350.6242.6237.75311-M614 to 15
SFC-060SA2A11241124684653.625.23.217.57.75311-M614 to 15
B1124Over 243517.526.5
COver 2430Over 243526.5
SFC-080SA2C183518408268308289381-M827 to 30
SFC-090SA2C254025459468.3308.3349421-M827 to 30
SFC-100SA2C3245324510469.8309.8399481-M827 to 30

* Types A / B / C are automatically specified by Miki Pulley according to the combination of bore diameters you select, and cannot be specified by the customer.

* The øDB value is measured assuming that the head of the clamping bolt is larger than the external diameter of the hub.

* The K dimension is the inner diameter of the element. For d2 dimension exceeding this value, shaft can be inserted only up to LF dimension to the d2 side hub.

* The nominal diameter for the clamping bolt M is equal to the quantity minus the nominal diameter of the screw threads, where the quantity is for a hub on one side.

* The figures in parentheses ( ) for the SFC-010 are the values when d1 or d2 is ø8 mm.

[Standard bore diameter]

Standard (option) bore diameter, d1/d2 [mm] and restricted rated torque [N∙m]
Nominal bore diameter34566.357899.52510111213141516171819202224252830323538404245
Shaft tolerance h7 (h6・g6)B
Shaft tolerance j6 (Option)J             
Shaft tolerance k6 (Option)K             
SFC-002SA2d1 
d2                           
SFC-005SA2d1 
d2                          
SFC-010SA2d1 
d2                       
SFC-020SA2d1  
d2                   
SFC-025SA2d1  2.1 
d22.1                
SFC-030SA2d1  2.83.4 
d22.83.4              
SFC-035SA2d1   556.6 
d2556.6           
SFC-040SA2d1      9 
d29        
SFC-050SA2d1      18202222 
d218202222     
SFC-055SA2d1         31343638 
d231343638     
SFC-060SA2d1          5051 
d25051   
SFC-080SA2d1                  
d2 
SFC-090SA2d1                       
d2
SFC-100SA2d1                         226
d2226

* The shaft tolerance for standard bore diameter is h7 (h6 or g6): designation B. However, for a bore diameter of ø35, the shaft tolerance is - 0.025 to +0.010.

* Shaft tolerances j6/k6: designations J/K are optional, and are only supported for bore diameters marked with ○ .

* Bore diameters marked with ● or numbers are supported as the standard bore diameters. Consult Miki Pulley regarding special arrangements which may be possible for other bore diameters.

* Bore diameters whose fields contain numbers are restricted in their rated torque by the holding power of the shaft connection component because the bore diameter is small. The numbers indicate the rated torque [N•m].

SFC-□DA2 Types

[Specifications]

ModelTypeRated torque
[N・m]
MisalignmentMax. rotation speed
[min-1]
Torsional stiffness
[N・m/rad]
Axial stiffness
[N/mm]
Moment of inertia
[kg・m2]
Mass[kg]
Parallel[mm]Angular[゜]Axial[mm]
SFC-002DA2C0.250.030.5(On one side)±0.081000095170.07×10-60.004
SFC-005DA2C0.60.050.5(On one side)±0.110000250700.37×10-60.010
SFC-010DA2C10.111(On one side)±0.210000700700.80×10-60.015
SFC-020DA2C20.151(On one side)±0.33100001850323.43×10-60.035
SFC-025DA2C40.161(On one side)±0.38100002800305.26×10-60.040
SFC-030DA2A50.181(On one side)±0.4100004000327.43×10-60.054
B9.45×10-60.060
C11.56×10-60.068
SFC-035DA2C100.241(On one side)±0.51000090005626.93×10-60.121
SFC-040DA2A120.241(On one side)±0.610000100004029.98×10-60.124
B35.82×10-60.131
C42.52×10-60.146
SFC-050DA2A250.281(On one side)±0.810000160002498.34×10-60.250
B118.9×10-60.268
C141.7×10-60.298
SFC-055DA2C400.311(On one side)±0.84100002500021.5261.3×10-60.459
SFC-060DA2A600.341(On one side)±0.9100003500038.2256.6×10-60.447
B315.7×10-60.489
C379.3×10-60.549
SFC-080DA2C1000.521(On one side)±1.101000070000641039×10-61.037
SFC-090DA2C1800.521(On one side)±1.301000050000541798×10-61.369
SFC-100DA2C2500.551(On one side)±1.48100006000055.52754×10-61.739

* Types A / B / C are automatically specified by Miki Pulley according to the combination of bore diameters you select, and cannot be specified by the customer.

* Check the "Standard Bore Diameters" as rated torque may be restricted by the holding power of the shaft connection component.

* Max. rotation speed does not take into account dynamic balance.

* Torsional stiffness values given are measured values for the element alone

* The moment of inertia and mass are measured for the maximum bore diameter.

[Dimensions]

Unit [mm]
ModelTyped1[mm]d2[mm]D[mm]DB[mm]N[mm]L[mm]LF[mm]LP[mm]S[mm]A1[mm]A2[mm]C[mm]d3[mm]K[mm]M
Qty - Nominal dia
Tightening torque[N・m]
Min. Max.Min. Max.
SFC-002DA2C35351212.415.75.92.80.553.71.95.25.61-M1.60.23 to 0.28
SFC-005DA2C36361623.27.855.514.82.56.56.51-M20.4 to 0.5
SFC-010DA2C38381925.99.155.51.055.8(6)3.158.58.51-M2.5(M2)1.0 to 1.1(0.4 to 0.5)
SFC-020DA2C4104112632.310.757.51.659.53.310.610.61-M2.51.0 to 1.1
SFC-025DA2C5145142932.810.757.51.9113.31514.51-M2.51.0 to 1.1
SFC-030DA2A5105103421.637.812.482.583.751514.51-M31.5 to 1.9
B510Over 1016812.5
COver 1014Over 101612.5
SFC-035DA2C616619394815.5113144.517171-M43.4 to 4.1
SFC-040DA2A8158154429.64815.5113114.52019.51-M43.4 to 4.1
B815Over 15241117
COver 1519Over 152417
SFC-050DA2A819819563859.820.5142.414.5626261-M57.0 to 8.5
B819Over 193014.522
COver 1925Over 193022
SFC-055DA2C103010306368.72415.52.6237.7531311-M614 to 15
SFC-060DA2A11241124684673.325.216.53.217.57.7531311-M614 to 15
B1124Over 243517.526.5
COver 2430Over 243526.5
SFC-080DA2C1835184082983022828940381-M827 to 30
SFC-090DA2C254025459498.630228.334947421-M827 to 30
SFC-100DA2C32453245104101.630229.839950481-M827 to 30

* Types A / B / C are automatically specified by Miki Pulley according to the combination of bore diameters you select, and cannot be specified by the customer.

* The øDB value is measured assuming that the head of the clamping bolt is larger than the external diameter of the hub.

* The K dimension is the inner diameter of the element. For d2 dimension exceeding this value, shaft can be inserted only up to LF dimension to the d2 side hub.

* The nominal diameter for the clamping bolt M is equal to the quantity minus the nominal diameter of the screw threads, where the quantity is for a hub on one side.

* The figures in parentheses ( ) for the SFC-010 are the values when d1 or d2 is ø8 mm.

[Standard bore diameter]

Standard (option) bore diameter, d1/d2 [mm] and restricted rated torque [N∙m]
Nominal bore diameter34566.357899.52510111213141516171819202224252830323538404245
Shaft tolerance h7 (h6・g6)B
Shaft tolerance j6 (Option)J             
Shaft tolerance k6 (Option)K             
SFC-002DA2d1 
d2                           
SFC-005DA2d1 
d2                          
SFC-010DA2d1 
d2                       
SFC-020DA2d1  
d2                   
SFC-025DA2d1  2.1 
d22.1                
SFC-030DA2d1  2.83.4 
d22.83.4              
SFC-035DA2d1   556.6 
d2556.6           
SFC-040DA2d1      9 
d29        
SFC-050DA2d1      18202222 
d218202222     
SFC-055DA2d1         31343638 
d231343638     
SFC-060DA2d1          5051 
d25051   
SFC-080DA2d1                  
d2 
SFC-090DA2d1                       
d2
SFC-100DA2d1                         226
d2226

* The shaft tolerance for standard bore diameter is h7 (h6 or g6): designation B. However, for a bore diameter of ø35, the shaft tolerance is - 0.025 to +0.010.

* Shaft tolerances j6/k6: designations J/K are optional, and are only supported for bore diameters marked with ○ .

* Bore diameters marked with ● or numbers are supported as the standard bore diameters. Consult Miki Pulley regarding special arrangements which may be possible for other bore diameters.

* Bore diameters whose fields contain numbers are restricted in their rated torque by the holding power of the shaft connection component because the bore diameter is small. The numbers indicate the rated torque [N•m].

Related Product