SYD Models
[Specifications]
Model | Motor | SYD-100/100-E | SYD-100/200-E | SYD-200/100-E | SYD-200/200-E | SYD-400-E | SYD-750-E | SYD-1500-E | |
---|---|---|---|---|---|---|---|---|---|
Control panel | SYD-100/100-□ | SYD-100/200-□ | SYD-200/100-□ | SYD-200/200-□ | SYD-400-□ | SYD-750-□ | SYD-1500-□ | ||
Rated output | [kW] | 0.1 | 0.1 | 0.2 | 0.2 | 0.4 | 0.75 | 1.5 | |
Rated torque | [N・m] | 0.39 | 0.39 | 0.78 | 0.78 | 1.56 | 2.92 | 5.84 | |
Rotation range | [min-1] | 0~2500 | |||||||
Speed change range | [min-1] | 125~2500 | |||||||
Power supply (AC) | Voltage | [V] | 100 | 200 | 100 | 200 | 200 | 200 | 200 |
Frequency/phase | Frequency/phase | Single phase, 50/60 Hz | |||||||
Allowable voltage fluctuation range | Allowable voltage fluctuation range | ±10% | |||||||
Current *1 | [A] | 2.3 | 1.2 | 4.5 | 2.3 | 4.5 | 9.0 | 18.0 | |
Output (DC) | Armature voltage | [V] | 80 | 160 | 80 | 160 | 160 | 160 | 160 |
Armature current | [A] | 1.7 | 0.85 | 3.2 | 1.6 | 3.0 | 6.0 | 11.5 | |
Magnetic field voltage | [V] | 85 | 175 | 85 | 175 | 175 | 175 | 175 | |
Magnetic field current | [A] | 0.09 | 0.14 | 0.09 | 0.17 | 0.23 | 0.27 | 0.38 | |
Motor type | Fully-closed C flange | Drip-proof C flange | |||||||
Rotor moment of inertia | [kg・m2] | 0.0010 | 0.0010 | 0.0016 | 0.0016 | 0.0016 | 0.004 | 0.007 | |
Fuse | Armature side *2 | FU1 [A] | 10 | 16 | 20 | ||||
Magnetic field side | FU2 [A] | 0.5 (glass tube) | |||||||
Control method | Consistent speed control by constant voltage, IR compensation and magnetic field temperature compensation | ||||||||
Components | DC motor, control panel | ||||||||
Standard operating specifications | Power supply switch/speed setter | ||||||||
Carbon brush | Model/number of brushes | SCD-100-BL / Qty. 2 | SYD-400-BL / Qty. 2 | SCD-400-BL / Qty. 4 | |||||
Dimensions | [mm] | 6×8×20 (H×W×L) | 8×6×24 (H×W×L) | ||||||
Control board mass | [kg] | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.7 | 3.8 | |
Motor mass | [kg] | 10.5 | 13.2 | 16.5 | 24.0 | 36.0 |
*1: Reference value.
*2: Use the specified fast-blow fuse.
*For the specifications of motors with brake and terminal box, refer to Options.
[Dimensions]
Model | SYD-100/100-E | SYD-200/100-E | SYD-400-E | SYD-750-E | SYD-1500-E |
---|---|---|---|---|---|
SYD-100/200-E | SYD-200/200-E | ||||
C | 75 | 75 | 75 | 90 | 112 |
D | 135 | 135 | 135 | 164 | 196 |
L | 230 | 263 | 303 | 354 | 429 |
XB | 60 | 75 | 75 | 95 | 130 |
M | 140 | 140 | 140 | 180 | 220 |
N | 110 | 110 | 110 | 130 | 170 |
E | 112 | 112 | 112 | 140 | 190 |
F | 90 | 90 | 90 | 100 | 140 |
J | 30 | 30 | 30 | 40 | 40 |
K | 20 | 20 | 20 | 30 | 50 |
G | 10 | 10 | 10 | 12 | 12 |
H | 150 | 150 | 150 | 179 | 243 |
Q | 25 | 25 | 25 | 40 | 60 |
QK | 20 | 20 | 20 | 30 | 50 |
S | 11 | 11 | 14 | 19 | 24 |
W | - | - | 5 | 5 | 7 |
U | - | - | 16 | 21 | 27 |
LA | 118 | 118 | 118 | 130 | 165 |
LB | 100 | 100 | 100 | 110 | 130 |
Y | M6 | M6 | M6 | M8 | M10 |
B | 3 | 3 | 3 | 3 | 4 |
Z | 7 | 7 | 7 | 10 | 12 |